Orthovita.com
PRODUCTS
COMPANY PROFILE
PATIENT INFORMATION
CAREERS
INVESTORS
CONTACT US
Skip Navigation Links

Cortoss Bone Augmentation Material - Bibliographies

Click a title to view a printable abstract

Biomechanics

Gheduzzi, S, Webb, JJC, Miles, AW. Mechanical Characterization of Three Percutaneous Vertebroplasty Biomaterials. J Mater Sci, Mater Med. 2006; 17: 421-426. View abstract here

Homminga, J, et al. Osteoporosis Changes the Amount of Vertebral Trabecular Bone at Risk for Fracture but not the Vertebral Load Distribution. SPINE. 2001; 26 (14): 1555-1561. View abstract here

Kim, MJ, et al. Vertebroplasty Versus Kyphoplasty: Biomechanical Behavior Under Repetitive Loading Conditions. Spine. 2006; 31(18): 2079-2084. View abstract here

Lou, J, et al. Mechanical Efficacy of Vertebroplasty: Influence of Cement Type, BMD, Fracture Severity, and Disc Degeneration. Bone. 2006, DOI:10.1016/j.bone.2006.11.021. View abstract here

Materials

Belkoff, SM, et al. Biomechanical Evaluation of a new Bone Cement for Use in Vertebroplasty. SPINE. 2000; 25 (9): 1061-1064.View abstract here

Deramond, et al., Temperature Elevation Caused by Bone Cement Polymerization During Vertebroplasty. Bone, 1999, 25(2), 17S-21S.View abstract here

DiCicco et al., In Vitro Evaluation of Orthopedic Composite Cytotoxicity: Assessing the Potential for Postsurgical Production of Hydroxyl Radicals. Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2005, 72B, 146-155.View abstract here

DiCicco et al., Tobramycin and Gentamycin Elution Analysis between Two in Situ Polymerizable Orthopedic Composites. Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2003, 65B, 137-149.View abstract here

Erbe, EM, Clineff, TD, Gualtieri, G. Comparison of a New Bisphenol-a-glycidyl dimethacrylate-based Cortical Bone Void Filler with Polymethyl Methacrylate. Eur Spine J. 2001; 10:S147-S152. View abstract here

Heini, PF, Berlemann, U. Bone Substitutes in Vertebroplasty. Eur Spine J. 2001; 10:S205-S213. View abstract here

Jasper, Deramond, et al., Material Properties of Various Cements for Use with Vertebroplasty. Journal of materials Science: Materials in Medicine, 2002, 13, 1-5. View abstract here

Lewis, G. Injectable Bone Cements for Use in Vertebroplasty and Kyphoplasty: State-of-the-Art Review. Wiley Interscience (www.interscience.wiley.com). 2005; DOI: 10.1002/jbm.b.30398. View abstract here

Pomrink et al., Evaluation of the Reaction Kinetics of CORTOSS, a Thermoset Cortical Bone Void Filler. Biomaterials, 2003, 1023-1031. View abstract here

Vertebral Compression Fractures

Cohen, JE, et al. Percutaneous Vertebroplasty: Technique and Results in 192 Procedures. Neurol Res. 2004; 26: 41-49. View abstract here

Jensen, ME, et al. Position Statement on Percutaneous Vertebral Augmentation: A Consensus Statement Developed by the American Society of Interventional and Therapeutic Neuroradiology, Society of Interventional Radiology, American Association of Neuological Surgeons/Congress of Neuological Surgeons, And American Society of Spine Radiology. Am J Neuroradioi. 2007; 28: 1439-1443. View abstract here

Mehbod, Aunoble, Le Huec, Vertebroplasty for Osteoporotic Spine Fracture: Prevention and Treatment. European Spine Journal, 2003, 12, S155-S162.View abstract here

Riggs, BL, Melton, LJ. The Worldwide problem of Osteoporosis: Insights Afforded by Epidemiology. Bone. 1995; 17: 505S-511S. View abstract here

Shen, M, Kim, Y. Osteoporotic Vertebral Compression Fractures: A Review of Current Surgical Management Techniques. Am J Orthop. 2007; 36(5): 241-248. View abstract here

Voormolen, MHJ, et al. Percutaneous Vertebroplasty Compared with Optimal Pain Medication Treatment: Short-Term Clinical Outcome of Patients with Subacute or Chronic Painful Osteoporotic Vertebral Compression Fractures. The VERTOS Study. Am J. Neuroradiol. 2007; 28: 555-560. View abstract here

Vertebral Compression Fractures (Cortoss)

Bae,H, et al. Characteristics and Clinical Experience Using a Novel Bioceramic for Treating Vertebral Compression Fractures in Vertebroplasty and Kyphoplasty: Report on the First 40 Patients. Proceeding of the NASS 20th Annual Meeting / The Spine Journal. 2005; 5: 1S-189S. View abstract here

Beric, V. Ultra-Low Volume Vertebroplasty Using Cortoss Bone Substitute. Scientific Paper (Oral Presentation) American Society of Neuroradiology. 2006. View abstract here

Pradhan, B, Bae, HW. Prospective Randomized Vertebroplasty Trial at a Single Institution: Cortoss Compared to PMMA. Poster Presentation; Congress of Neurological Surgeons. 2007. View abstract here

Palussiere, J, et al. Clinical Results of an Open Prospective Study of a bis-GMA Composite in Percutaneous Vertebral Augmentation. Eur Spine J. 2005; 14: 982-991. View abstract here

Subsequent Fracture

Berlemann, U., Ferguson, S.J., Nolte, L.P., Heini, P.F. Adjacent vertebral fracture after vertebroplasty: A biomechanical investigation. The Journal of Bone & Joint Surgery (Br). 2002; 84-B(5): 748-752. View abstract here

Fribourg, D et al. Incidence of Subsequent Vertebral Fracture after Kyphoplasty. SPINE. 2004; 29 (20): 2270-2276.View abstract here

Lin, E. P. Et al. Vertebroplasty: Cement Leakage into the Disc Increases the Risk of New Fracture of Adjacent Vertebral Body. American Journal of Neuroradiology. 2004; 25: 175-180. View abstract here

Syed, M. I. et al. Intradiskal Extravasation with Low-Volume Cement Filling in Percutaneous Vertebroplasty. American Journal of Neuroradiology. 2005; 26: 2397-2401. View abstract here

Trout, A. T., Kallmes, D. F., Kaufmann, T. J. New Fractures after Vertebroplasty: Adjacent Fractures Occur Significantly Sooner. American Journal of Neuroradiology. 2006; 27: 217-223. View abstract here

Injection Volume

Belkoff, SM, et al. The Biomechanics of Vertebroplasty: The Effect of Cement Volume on Mechanical Behavior. Spine. 2001; 26(14): 1537-1541. View abstract here

Liebschner, M. A. K., Rosenberg, W. S., Keavney, T. M. Effects of Bone Cement Volume and Distribution on Vertebral Stiffness after Vertebroplasty. SPINE. 2001; 26(14): 1547-1554. View abstract here

Molloy S, Mathis, J, Belkoff, S. M. The Effect of Vertebral Body Percentage Fill on Mechanical Behavior During Percutaneous Vertebroplasty. SPINE. 2003; 28(14): 1549-1554. View abstract here



Vitoss
Imbibe
Cortoss
Vitagel
Vitasure